Microplate readers detect and process biological and chemical data using absorbance (ELISAs, enzyme activity, and nucleic acid and protein quantification), luminescence, and fluorescence detection modes, including intensity, TRF, and polarization. Turn the reader on and secure the USB cable. Use a Phillips screwdriver to remove the screws, and then remove the plate from the instrument. The SpectraMax M2/M2e User Guide is a comprehensive manual that provides detailed instructions on how to operate, maintain, and troubleshoot the SpectraMax M2 and M2e microplate readers. Instrument settings can be saved as a protocol file. The plate reader optics are tunable for absorbance. Bandwidth for both excitation and emission is 9 nm. PathCheck sensor corrects optical pathlength & pipetting variation. Table of Contents. With three modes of detection for full spectrum absorbance, fluorescence and luminescence, the SpectraMax® Mini reader . The top- and bottom-reading Gemini EM Microplate Reader with dual monochromators lets users determine the optimal excitation and emission settings for creative new fluorescence. The plate is set up for reading and images are acquired accordingSpectraMax Readers have the most complete level of product validation and compliance. In addition, the iD5 reader measures TRF and FP and. For nearly 30 years, Molecular Devices has provided scientists with . The SpectraMax Paradigm reader with HTRF Detection Cartridge offers high-throughput screening capability with excellent read times and Z’ factors. Recertification service. 020 OD 2. Catalog Number i3x. 4: Test tube cover. visible absorbance, fluorescence. IMAP® Technology from Molecular Devices enables rapid, homogeneous, and non-radioactive assay of kinases, phosphatases, and phosphodiesterases and is suited for both assay development and high-throughput screening. The SpectraMax 190 reader can be integrated with Molecular . Narrow bandwidths deliver increased accuracy and enhanced peak resolution. With optimized reagents, option to operate the. Figure 10: The Plate section Template Editor, showing the series set up. From plate readers to high-content imagers, Molecular Devices has the instruments you need to advance your discovery. 1 up to 3600 sec. After centrifugation, the plate was immediately read on the M5e and i3x readers using the instrument settings listed in Table 1. Next generation SpectraMax® absorbance microplate readers. in steps of 0. Set up the instrument and software. M5. Open the Protocol Library, locate the ‘Protein Quant’ folder, and open the pre-configured protocol ‘NanoOrange’. The FlexStation 3 Reader combines Molecular Devices’ SpectraMax® M5e Microplate Reader performance with an integrated 8- or 16-channel pipettor into one compact benchtop reader. This can increase throughput and efficiency, thus saving time and space in the lab. The variations include adjustable speed and volume, adjustable aspiration speed and time, adjustable soak times, and three modes of. Microplate spectrophotometers, also called microplate readers, allow researchers to analyze multiple samples in parallel using 6- to 1536-well formats, as opposed to single sample measurements. The SpectraMax® M2 and M2e Systems from Molecular Devices are multi- detection microplate readers with dual- monochromators, dual-mode cuvette ports, and top- and bottom-reading capability (top-reading only on the M2). Feb 22, 2023Used. 76358-624. Molecular Devices SoftMax ® Pro software was used to analyze and present the data. Find our technical support information along with contact details. ” So, acquisition and analysis come from one software system. Cells in each. 20-plate magazine (pair) 0200-6016. Compact designs. The VMax Microplate Reader is capable of reading up to two wavelengths at a time in the visible wavelength spectrum (400nm-750nm), with 4 filter choices included at time of purchase. Nanoracks’ Plate-Reader-2 (2nd generation) is a reconfigured Molecular Devices SpectraMax M5e – one of the most reliable, durable, feature-rich microplate readers on. We would like to show you a description here but the site won’t allow us. Features technology from the SpectraMax i3x and MiniMax 300 Imaging Cytometer. Get a front row view of your cells. 314 low lamp level warning. SpectraMax ABS and ABS Plus Absorbance ELISA Microplate Readers. These systems are hybrids that allow you to choose between. The Back Panel Figure 1. plate shaker and incubate for 2 to 5 minutes at room temperature, protected from light. SoftMax® Pro Software for Windows 10 and 11 is designed to provide the simplicity, flexibility and power required for advanced data analysis. The VersaMax™ Microplate Reader from Molecular Devices bridges the gap between the affordability of filter-based readers and the flexibility of monochromator-based systems. S. OPTICS Mirrored optics focus the light into the sample volume, and cutoff filters are used to. Gemini XPS & EM readers measure fluorescence on a variety of sample formats from 6- to 384-well microplates. 1). The dual monochromator optics allow the widest range of applications to be utilized for bioresearch and drug discovery applications, all without the need to change. It is more inert and reduces compound interference. A preconfigured. 635. #0200-7011) Instrument setup SOP Title: Use and Maintenance of a Molecular Devices M5 Plate Reader Document ID: HSL_EQ_005 Version 2. 1. Read height should be optimized for Vmax® plate reader specifications. Fortunately, Molecular Devices’ SpectraMax i3x and iD5 readers offer the best of both worlds. The SpectraMax® M2 and M2e Systems from Molecular Devices are multi- detection microplate readers with dual- monochromators, dual-mode cuvette ports, and top- and. Step 4: Incubate at room temperature for 1 hour, protected from light. 2 Software Release Notes. 0112-0127C 9 Chapter1:Introduction TheFlexStation® 3Multi-ModeMicroplateReadercombinestheperformanceofadual-monochromator,multi-modemicroplatereaderandanintegrated8. Measure more accurately. These tools can be used in conjunction with SoftMax® Pro Software validation package and IQ/OQ/PQ validation protocols for FDA 21 CFR Part 11 compliance. 5 minutes (ValitaTiter) 15 minutes (ValitaTiter PLUS) Integrating ValitaTiter and Molecular Devices fluorescence polarization (FP) plate readers produces a seamless IgG titer assay setup and optimization. M5. : 8 Oct 12 Page 1 of 10 Setup Guide on the Molecular Devices SpectraMax® M5/M5e Microplate Reader Have a question? Contact our Technical Support Team NA: 800-955-6288 or INTL: 760-603-7200 ext. 2 GxP Software is our most secure software to help you achieve full FDA 21 CFR Part 11 compliance with streamlined workflows to ensure data integrity. United States Phone: 800-635-5577 408-747-1700. The instruments feature a bottom-read mode ideal for whole-cell-based assays, and may beSoftMax Pro GxP Software. 0 . Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a. SpectraMax® Absorbance Microplate Readers can run both cuvette-based and microplate reader applications on the same instrument. Load up the plates that you need to run and walk. Plate stacker and robot integration The SpectraMax 340PC384 reader can be integrated with Molecular Devices’ StakMax® Microplate Stacker in a matter of minutes and begin reading microplates with seven mouse clicks. Specialized filters allow for IR fluorescence detection ranging from 10-40 times more sensitive than conventional monochromator detection reader. It provides ready-to-run protocols, analysis algorithms, and 21 different curve fit options. 00 USD. The instrument is designed to regulate the temperature of the plate chamber from 5°C above ambient to 45°C. Set up Identify Acquire Analyze Imaging with the SpectraMax MiniMax Imaging Cytometer mirrors the plate reading workflow on the SpectraMax i3 System. For the name of the nearest authorized Molecular Devices Corporation service facility, please contact Molecular Devices at one of the following telephone numbers: (408) 747-1700 (800) 635-5577 (U. Tristar 3 Multimode Microplate Reader. Remove the lamp screw (on the right side of the lamp, as shown in the diagram) then gently pull the connecting wires to remove the lamp from the body of the instrument. 세포신호전달은 세포가 환경에 반응하고 다른 세포와 소통할 수 있게 합니다…. A plate containing two columns each of 75 µL, 100 µL, 150 µL, 200 µL, 250 µL, or 300 µL of yellow buffer solution was read at 426 nm on a SpectraMax microplate reader. The SpectraMax® iD5 Multi-Mode Microplate Reader is the complete laboratory solution to help you increase your research capabilities and comes with built-in absorbance, fluorescence, luminescence, time-resolved fluorescence (TRF), and tunable fluorescence polarization (FP) read modesRobust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter. D SpectraMax ® M2 SpectraMax ® M2 e Multimode Plate Readers User Guide Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089. Detection modalities include absorbance (UV-Vis Abs) and fluorescence intensity (FI). Since cells are nearly confluent, the protocol. In addition, the iD5 reader measures TRF and FP and can be expanded to include TR-FRET, HTRF®, BRET, dual luciferase reporter assays with injectors, and western blot detection. 0 × 107) RLU 0. . It has dual scanning monochromators that allow for 1 nm increment selection over the wavelength range of 250 - 850 nm. If no sound is heard during initialization, contact technical support. 1. 303 unable to cal dark current. An absorbance plate reader offers higher throughput and can measure the absorbance of samples in microplates (typically 96-well or even 384-well) by sending light through each well. ELISA (Enzyme-linked Immunosorbent Assay) is one of the most popular quantitative methods to detect a target antigen such as toxin or foreign substance within a sample. The adapter is required for optimum performa nce with standard 96-well and 384-. The ultimate guide to microplate readers is an eBook that tells you everything you need to know about plate reader solutions from what a microplate reader is, to popular applications and technology, to GxP compliance and special tips and tricks to help maximize your. The plate reader optics are tunable for absorbance, fluorescence intensity, fluorescence polarization, and time resolved fluorescence assays (TRF). Page 1 SpectraMax M2/M2 user guide ® A MULTI-DETECTION MICROPLATE READER WITH TWO-MODE CUVETTE PORT. Read one sample or up to 384 in a single plate read using any standard cuvette, 12 x 75 mm test tube, or 96- or 384-well microplate. Figure 1. Luminescence was read every five minutes for five hours with three seconds of orbital shaking before each read. SpectraMax® 190 Absorbance Plate Reader, Molecular Devices Supplier: Molecular Devices Enables data acquisition in endpoint, kinetic, and spectral scan modes at wavelengths across the UV-visible wavelength. Accurate and sensitive detection of nucleic acids and proteins are critical to many experiments. The SpectraMax® M2 and M2e Systems from Molecular Devices are multidetection microplate readers with dualmonochromators, dual-mode cuvette ports, and top- and bottom-reading capability (top-reading only on the M2). Step 2: Launch SoftMax Pro Software. Read times. The SpectraMax ABS Plus reader utilizes Molecular . 5577; General Inquiry Form; Mon-Fri 8:00am - 5:00pmFor the SpectraMax M3/M4/M5 readers - use the Purple Assay Plate adapter for Top Read only. Supersedes 1. On the back, in the right hand top corner, there. , attenuation mode = out. The SpectraMax® iD3 Multi-Mode Microplate Reader is the cornerstone of a complete laboratory solution designed to expand the boundaries of research capabilities. Cell line development teams will realize savings on time and resources,Some plate readers handle label-free cell-based assays, such as PerkinElmer’s EnSpire® multimode reader, which in addition to absorbance, luminescence, fluorescence and AlphaLISA also supports Corning’s Epic® technology. What are the Vmax plate reader specifications? Recommended Articles SoftMax® Pro 7. Description Figure 1. The SpectraMax M5 features a triple-mode cuvette port and a single-read command capability for experiments requiring multiple detection parameters. (7) Anastellin impacts on the processing of extracellular matrix fibronectin and stimulates release of cytokines from coronary artery smooth muscle cells. First choose Read Mode ‘FL’ and Read Type ‘Endpoint’, and then select. ; Page 2 Molecular Devices equipment, software, reagents, and consumables. With the SpectraMax® MiniMax™ 300 Imaging Cytometer, industry-leading SoftMax® Pro Software, and user. and California) Tunable Microplate Reader 100-240V ~ 4A 50-60 HZ T4. If the computer is connected to the Internet: Select Search Automatically for. Learn how you can utilize microplate readers to drive landmark discoveries. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. This reader's dual monochromators for. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. The plate reader optics are tunable for absorbance, fluorescence intensity, fluorescence. VMax . #0200-6263) UltraVision™ Plate 384 (Brooks Life Sciences cat. Uncontrolled Copy for Training and Reference Purposes Only . SpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A 1. in steps of 0. Successful targets include calcium channels, chemokine receptors, and transiently transfected receptors. #iD3) Methods. Built around a grating monochromator, the VersaMax™ Absorbance Microplate Reader allows for selection of up to two wavelengths at a time for absorbance detection in the visible wavelength range (340–850nm). 0 EU/mL, but the additional standard concentration (0. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. Microscopes and Microplate Instrumentation. Table 3 shows sample cell proliferation assay results for CHO-K1 cells plated according to the scheme in Table 1 and allowed to proliferate in culture for two days. The absorbance (A405) can be measured by the plate reader and is proportional to the endotoxin concentration in the sample. Lift up the lid over the chamber to insert or remove a cuvette. A standard spectrophotometer measures the absorbance of one sample at a time. SpectraMax 340 (Serial number starting with M) SpectraMax 340PC (Serial number starting with L) SpectraMax Plus (Serial number starting with P) Tmax Also refer. 0 × 103 to 2. Enables data acquisition in endpoint, kinetic, and spectral scan modes at wavelengths across the UV-visible wavelength range, with the only temperature-independent method of pathlength correction. Laboratory automation workflows can help. Visualize cells with your microplate reader Imaging with the SpectraMax MiniMax 300 Imaging Cytometer mirrors the plate reading workflow on the SpectraMax i3x System. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire. Plus 384. IMAP assays are based on binding of. This process should take about 3 - 5 minutes. Lastly, we demonstrate the utility of this novel fluorescence-based assay to evaluate the activities of. View SoftMax Pro GxP. For customers outside the U. The Molecular Devices FilterMax F5 (replacing our old Analyst plate reader) is a versatile instrument that offers detection based on fluorescence, fluorescence polarization, luminescence, absorbance, and time resolved FRET. Ratios for each sample were calculated as Read B/Read A. S. 1-2 sec. Gregory et al. To contact technical support by phone in the U. Perform plate-based assays on a large number of plates without having to manually feed them into your microplate washer and reader. D 1. The Molecular Devices SpectraMax M5E is a multi-mode plate reader that delivers single mode reader performance with five preferred detection modes for a wide range of applications. Page 1 of 8 . Molecular Devices launches custom organoid line expansion service using unique bioprocess technology for high-throughput applications. The FLIPRTETRA, which debuts today at. SpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. Used. QuickSync. Cellular Imaging Systems. 1. The perfect microplate reader for everyday biochemical assays, cell-based assays, molecular. AXON Patch-Clamp. Contains one microplate adapter, five 24-well low volume slides, five 64-well low volume bottom slides, and five of each cover slide (2 µL and 4 µL) 0200-6267. Plate. For a higher degree of automation, the Automation Vendor Partners Program has streamlined the integration of our microplate reader s with allSpectraMax® iD5 Multi-Mode Microplate Reader - Five-Mode Hybrid Microplate Reader with Automatic NFC Filter Identification and Western Blot Capability, Molecular Devices. The purpose of this procedure is to set instructions in the proper use and handling of the Molecular Devices M5 Plate Reader. It provides ready-to-run protocols, analysis algorithms, and 21 different curve fit options. Molecular Devices SpectraMax Gemini XS Microplate Reader. SpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A 1. Step 2: Add sample to well – antigen within the sample binds to the capture antibody. The plate reader temperature was set to 37°C and allowed to reach 37°C before proceeding. Imaging System Giles Scientific Biomic V3 Automatic Plate. Fluorescence analysis was performed using a SpectraMax iD3 multi-mode plate reader (Molecular Devices LLC, U. Monitor reader performance on demand to ensure data quality is not compromised between PM/OQ. 0 software Download page. Note: removal of medium, followed by addition of a 1X solution of calcein AM and EthD-III, is. The SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers measure absorbance, fluorescence, and luminescence. Beyond the hardware, a microplate reader’s software also impacts performance and flexibility. The VMax® Microplate Reader is capable of reading up to two wavelengths at a time in the visible wavelength spectrum (400nm–750nm), with 4 filter choices included at time of purchase. 0 . SpectraMax MiniMax 300 imaging cytometer enables quick imaging and analysis of cells and helps in observing the viability of your cells with the field-upgradeable cellular imaging for spectramax i3/i3x multi-mode detection platform. The SpectraMax® Paradigm® Multi-Mode Microplate Reader measures absorbance, fluorescence, time-resolved fluorescence (including HTRF), fluorescence polarization, AlphaScreen®, AlphaLISA®, and luminescence assays for up to 1536-well plates. Molecular Devices' microplate readers. 4: Test tube cover. Summary of Contents for Molecular Devices SpectraMax M2. Fluorescence Microplate Reader Comparison Chart. Prior to fluorescence analysis, the lid from the OmniTray plate was removed. +44-118-944-8000. 2. The reader measures both flat and round 96-well microplates and. EUROPE. Page 1 of 8 . The ultimate guide to microplate readers is an eBook that tells you everything you need to know. Molecular Devices, LLC Optical System: Inquire; Measuring Time: White light - 96-well/ 384 well microplate: <2 min Fluorescence - 96-well/ 384 well microplate: <8 min. Molecular Devices' microplate readers. Set up template in SoftMax Pro and read plate on the SpectraMax M5 microplate reader: Note: IMAP FP protocols for use with FAM- and TAMRA-labeled substrates are available in SoftMax Pro 5 in the Binding Assays protocol folder. Molecular Devices SpectraMax Gemini XS Microplate Fluorometer. The plate reader can measure multiple readouts, including UV and. In labs where throughput is a top priority, a device that can screen 96- to 1536-well microplates in under one minute is worthwhile. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the. Plate chamber design of the SpectraMax category 1 microplate readers. Upgradeable modules are also available. Temperature Control 4°C above ambient to 45°C. Step. Longside barcode reader: 0310-5101. The SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers measure absorbance, fluorescence, and luminescence. Read one sample or up to 384 in a. Description: The SpectraMax® iD5 Multi-Mode Microplate Reader is the complete laboratory solution to help you increase your research. Instrument settings can be saved as a protocol file. Published Dec 16, 2020 | Updated Dec 16, 2020. VIS absorbance detection. #I3X), equipped with the following: HTRF Detection Cartridge (Molecular Devices cat. From plate readers to high-content imagers, Molecular Devices has the instruments you need to advance your discovery. Details. In addition, the iD5 reader measures TRF and FP and can be expanded to include TR-FRET, HTRF®, BRET, dual luciferase reporter assays with injectors, and western blot detection. Additional high-quality filters to supplement your assay wavelength range requirements are available directly from Molecular Devices. Integrated stacker option. 1700 +1 800. The direct transfer capability reduces We would like to show you a description here but the site won’t allow us. Instrument design, user interface capabilities, and cost play key roles in purchasing a suitable microplate reader. Data collection speed is sufficient for running fast cell-based kinetic assays. D SpectraMax ® M2 SpectraMax ® M2 e Multimode Plate Readers User Guide Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part #0112-0102 Rev. This eBook shows how to see more and do more with an imaging cytometer that enables rapid imaging and cell analysis. Important things to consider when purchasing a multimode microplate reader. with the kit reagent and transferred to the plate reader for evaluation at the same time. 1. Learn how you can utilize microplate readers to drive landmark discoveries. Explore more about the SpectraMax i3x Multi-Mode Plate Reader, a user-upgradeable detection modules allow you to expand the capabilities of your microplate reader when your research requires it. This document outlines references to 21 CFR Parts 58, 211 and 820 and EudraLex Annex 15 to assess the implementation of Molecular Devices microplate readers in regulated environments. . For biochemical assays, the washer removes unbound material and unreacted reagents. Optimize. SoftMax® Pro Software Version 5 for Mac and Windows User Guide 5000938 B June 2010 SoftMaxPro_UserGuide_5000938. SoftMax Pro 7. TheUnparalleled performance on a personalized platform. 747. Turn on Plate Reader and wait for it to complete its start-up routine. Perform the following steps to install the drivers: Start > Control Panel > System. As new assays are developed or your needs change, simply add a detection cartridge like ScanLater™ Western Blot System or the SpectraMax® MiniMax™ Imaging Cytometer option as opposed to buying a brand new system. The MultiWash+™ Microplate Washer is an automated, compact, quiet, efficient washer with 20 different wash protocol options. The SpectraMax® M5 Multi-Mode Microplate Reader delivers single mode reader performance in one multimode reader package. Wait 20 seconds. 0112-0126B 8 Chapter1:Introduction TheSpectraMax®340PC384,SpectraMax®190,andVersaMax™microplate. Experimental details and customization of the group table. Figure 9. the use of a reader calibrated with primary NIST and NMI standards. Results shown are from the SpectraMax M5 microplate reader, but similar results are obtained with other Molecular Devices readers with fluorescence detection mode (data not shown). BMG Labtech - THERMOstar. Increase productivity with patented microplate reader technologies. Chirag Patel, a graduate student at Johns Hopkins, reviewed Molecular Devices' SpectraMax M5 Multi-Mode Microplate Reader and found it an excellent resource for his lab's research on mTOR signaling in CD8 T cells. One plate carrier adapter is provided with the instrument. The top- and bottom-reading Gemini EM Microplate Reader measures fluorescence on a variety of sample formats from 6- to 384-well microplates in endpoint, kinetic, spectral scan, and well-scan modes. #0200-7011) Instrument setupSOP Title: Use and Maintenance of a Molecular Devices M5 Plate Reader Document ID: HSL_EQ_005 Version 2. Introduction. The following components are located on the back panel of the SpectraMax and VersaMax readers: • Power switch:Chapter 1: Introduction The SpectraMax iD3 Multi-Mode Microplate Reader from Molecular Devices is a monochromator-based, multi-mode plate reader. Instrument settings can be saved as a protocol file. View the Molecular Devices website. Scanning options are endpoint, kinetic, spectral. The adapter is required for optimum performa nce with standard 96-well and 384-. High-precision 9 channel system; filter-less with up to 6 wavelengths. 2. Molecular Devices announced today the launch of the new SpectraMax ® iD5 Multi-Mode Microplate Reader, a feature-rich platform that expands the boundaries of scientific research. The plate reader optics are tunable for absorbance, fluorescence intensity,. One plate carrier adapter is provided with the instrument. 313 reference gain check fail. • Fluorescence Polarization (FP-FLUO) Detection Cartridge (Molecular Devices cat. Weight. Instrument settings can be saved as a protocol file. 1. Three low volume 24-well bottom slides. The dual monochromator optics allow the widest range of applications to be utilized for bioresearch and drug discovery applications, all without the need to change. Temperature control and shaking come standard. (1) Repertoires of SARS-CoV-2 epitopes targeted by antibodies vary according to severity of COVID-19 Virulence December 31, 2022 David J. 더 많은. The ability to accurately quantitate cell number in multi-well microplates enables a multitude of biological applications that study cell health or proliferation. 1) is a fluorescence plate reader that can measure intracellular Ca 2+ concentration using both single- and dual-wavelength fluorescent probes. Products : General, FilterMax F5 reader. Description: The SpectraMax® iD5 Multi-Mode Microplate Reader is the complete laboratory solution to help you increase your research. Also refer to the Multimode Reader Comparison Chart Features. 0) at 37 °C, fluorescence intensity was recorded on a Spectramax M5 Multimode plate reader (Molecular Devices, USA) at each timepoint. Microplate Readers. This document is provided to customers who have purchased Molecular Devices, Inc. Products : SpectraMax M2/M2e reader, SpectraMax M5/M5e reader, Gemini XPS reader, FlexStation II (Obsolete), Gemini EM reader, FlexStation 3 reader. (“Molecular Devices”) equipment, software, reagents, and consumables to use in the operation of such Molecular Devices equipment, software, reagents, and consumables. SpectraMax® iD5 Multi-Mode Microplate Reader - Five-Mode Hybrid Microplate Reader with Automatic NFC Filter Identification and Western Blot Capability, Molecular Devices. The plate was then read on Molecular Devices microplate readers with luminescence detection mode (Read A). SpectraMax M series, Gemini, and SpectraMax iDx readers have xenon flash lamps,. Eight filters enable visible-wavelength absorption measurement applications such as protein quantification, cell viability and ELISA. While many companies make instruments to detect and measure luciferase activity, identifying the right instrument for you can be difficult because of their high degree of feature variability. Nanoracks’ Plate-Reader-2 (2nd generation) is a reconfigured Molecular Devices SpectraMax M5e – one of the most reliable, durable, feature-rich microplate readers on the market. Tunable, filterless flexibility The VersaMax reader uses a grating monochromator to select the wavelength, so the exact wavelength needed can be selected for every assay. Used. STAKMAX. SpectraMax Microplate Readers. 0. A). 5032018C 8 Chapter1:Introduction TheEMax® PlusMicroplateReaderisafilter-basedabsorbancemicroplatereaderwitheight standardfiltersforawiderangeofapplications. Absorbance Plate Reader Comparison Chart. Extended linear dynamic range. FLIPR. The SpectraMax® i3x Multi-Mode Detection Platform measures spectral-based absorbance, fluorescence, and luminescence with the added functionality of modular upgrades for western blot, imaging, and fast kinetics with injectors. #0200-7009) Optimal instrument settings for ValitaTiter (P/N VAL003 or VAL013, left table) and ValitaTiter Plus (P/N VAL004 or VAL014, right table) assays on the SpectraMax i3x reader are shown below. 1. The plate reader optics are tunable for absorbance,. 4: Test tube cover. Imaging with the MiniMax 300 Cytometer mirrors the plate reading workflow on the SpectraMax i3x System. Shop now. 5: Schematic of the back panel of a reader. The SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers measure absorbance, fluorescence, and luminescence. We would like to show you a description here but the site won’t allow us. Enable more assay conditions Define individual reagents to be delivered to each well reducing reagent consumption and allowing for more assay conditions to be explored on a single microplate. 0A-Sunnyvale, CA-Made in USAMolecular Devices SpectraMax M5 User Manual (86 pages) Multi-Mode Microplate Readers. Search. A plate reader’s software may offer automated analysis using protocols configured for a particular assay. Products : General, Microplate Readers. 0 . PURPOSE. FAST AND ACCURATE METERTECH Microplate Reader $3,650. With the novel filter system, assays such as hydrogen peroxide detection assays and IRantibody-binding assays can be run confidently with Molecular Devices set ofOn SpectraMax L, 1 RLU = 1 count per second for photon counting mode only. Flexible integration options. The Back Panel Figure 1. AlphaScreen assays cannot be done on the SpectraMax M series, Gemini, and SpectraMax iDx (iD3/iD5) readers. . 7°C and the bottom to 36. Fortunately, Molecular Devices’ SpectraMax i3x and iD5 readers offer the best of both worlds. Molecular Devices Flourmeteric Imaging. The PathCheck Sensor is a revolutionary new awardwinning1 technology in SpectraMax® Instruments for measuring the fluid level in every well of a microplate 2–5. 96-well plate and 12,500-20,000. Create custom fluorescence assays without having to purchase expensive filter sets. SpectraMax iD5 Multi-Mode Microplate Reader, a hybrid monochromator- and filter-based, five-mode plate reader with automatic filter identification and western blot capability. When the user applies a set temperature of 37°C, the top is heated to 37. 00.